Citations
...standing on the shoulders of giants
[Benard of Chartres 12th Century, Isaac Newton 1676]
Every user who makes use of the CTLab resources is benefitting from many years of investment and, research and development work carried out within the Applied Mathematics Department at ANU.
As a condition of access to CTLab resources at educational rates, users are required to:
- advise us of any resulting publications.
- cite the following papers as appropriate to their work.
Users are also highly encouraged to add appropriate Applied Math's authors to any published work (we can advise on who is key contributor).
This will help us ensure the future of accessible cutting-edge CT resources at this national facility.
Example text to be inserted into publications
<Sample> was scanned at the 'National Laboratory for X-ray Micro Computed Tomography (CTLab)' based at the Australian National University (ANU) using a HeliScan MicroCT system with an optimized space-filling trajectory1 to yield sharp images2,3 at a resolution of <insert value> μm.
1 Kingston A, Myers G, Latham S, B. Recur, H. Li, Sheppard A
Space-Filling X-Ray Source Trajectories for Efficient Scanning in Large-Angle Cone-Beam Computed Tomography
IEEE Transactions on Computational Imaging, vol. 4, no. 3, pp. 447-458, Sept. 2018 (2008) c534-C548
Space-Filling X-Ray Source Trajectories for Efficient Scanning in Large-Angle Cone-Beam Computed Tomography
IEEE Transactions on Computational Imaging, vol. 4, no. 3, pp. 447-458, Sept. 2018 (2008) c534-C548
2 Latham S, Varslot T, Sheppard A
Automated registration for augmenting micro-CT 3D images
Computational Techniques and Applications Conference (CTAC 2008) (2008) c534-C548
Automated registration for augmenting micro-CT 3D images
Computational Techniques and Applications Conference (CTAC 2008) (2008) c534-C548
3 Myers G, Kingston A, Varslot T, Sheppard A
Extending reference scan drift correction to high-magnification high-cone-angle tomography
Optics Letters 36, 24(2011) 4809-4811
Extending reference scan drift correction to high-magnification high-cone-angle tomography
Optics Letters 36, 24(2011) 4809-4811
Key papers
Optimised CT scanning with a space-filling trajectory
Kingston A, Myers G, Latham S, B. Recur, H.Li, Sheppard A
Space-Filling X-Ray Source Trajectories for Efficient Scanning in Large-Angle Cone-Beam Computed Tomography
IEEE Transactions on Computational Imaging, vol. 4, no. 3, pp. 447-458, Sept. 2018.
Space-Filling X-Ray Source Trajectories for Efficient Scanning in Large-Angle Cone-Beam Computed Tomography
IEEE Transactions on Computational Imaging, vol. 4, no. 3, pp. 447-458, Sept. 2018.
Sharp images from CT scanning
Latham S, Kingston A, B. Recur, Myers G, O. Delgado-Friedrichs, Sheppard A
Reprojection Alignment for Trajectory Perturbation Estimation in Microtomography
IEEE Transactions on Computational Imaging, vol. 4, no. 2, pp. 271-283, June 2018. 38, 9(2011) 4934-4945
Reprojection Alignment for Trajectory Perturbation Estimation in Microtomography
IEEE Transactions on Computational Imaging, vol. 4, no. 2, pp. 271-283, June 2018. 38, 9(2011) 4934-4945
Kingston A, Sakellariou A, Varslot T, Myers G, Sheppard A
Reliable automatic alignment of tomographic projection data by passive auto-focus
Medical Physics 38, 9(2011) 4934-4945
Reliable automatic alignment of tomographic projection data by passive auto-focus
Medical Physics 38, 9(2011) 4934-4945
Myers G, Kingston A, Varslot T, Sheppard A
Extending reference scan drift correction to high-magnification high-cone-angle tomography
Optics Letters 36, 24(2011) 4809-4811
Extending reference scan drift correction to high-magnification high-cone-angle tomography
Optics Letters 36, 24(2011) 4809-4811
High resolution Helical CT scanning
Varslot T, Kingston A, Myers G, Sheppard A
High-resolution helical cone-beam micro-CT with theoretically-exact reconstruction from experimental data
Medical Physics 38, 10(2011) 5459-5476
High-resolution helical cone-beam micro-CT with theoretically-exact reconstruction from experimental data
Medical Physics 38, 10(2011) 5459-5476
Registration of multiple datasets
Latham S, Varslot T, Sheppard A
Automated registration for augmenting micro-CT 3D images
Computational Techniques and Applications Conference (CTAC 2008) (2008) c534-C548
Automated registration for augmenting micro-CT 3D images
Computational Techniques and Applications Conference (CTAC 2008) (2008) c534-C548
Latham S, Varslot T, Sheppard A
Image registration: Enhancing and Calibrating X-ray Micro-CT Imaging
International Symposium of the Society of Core Analysts 2008 (2008) 12
Image registration: Enhancing and Calibrating X-ray Micro-CT Imaging
International Symposium of the Society of Core Analysts 2008 (2008) 12
Dynamic tomography
Myers G, Kingston A, Varslot T, Turner M, Sheppard A
Dynamic tomography with a priori information
Applied Optics 50, 20(2011) 3685-3690
Dynamic tomography with a priori information
Applied Optics 50, 20(2011) 3685-3690
Myers G, Geleta M, Kingston A, Recur B, Sheppard A
Bayesian approach to time-resolved tomography
Optics Express 23, 15(2015) 20062-20074
Bayesian approach to time-resolved tomography
Optics Express 23, 15(2015) 20062-20074
Drishti
Limaye A
Drishti: a volume exploration and presentation tool
Proc. SPIE, Developments in X-Ray Tomography VIII 8506 (2012)
Drishti: a volume exploration and presentation tool
Proc. SPIE, Developments in X-Ray Tomography VIII 8506 (2012)
Updated: 23 December 2024/ Responsible Officer: Director, RSPE/ Page Contact: Webmaster, RSPE